Bore size(mm) | 4 | 6 | 10 | 12 | 16 | |||
Acting type | Double acting、Single acting_Push | Double acting、Single acting | ||||||
Fluid | Air(to be filtered by 40 μ m filter element) | |||||||
Operating pressure | Double acting | 0.2~0.7MPa(28~100psi)(2.0~7.0bar) | 0.15~0.7MPa(22~100psi)(1.5~7.0bar) | |||||
Single acting | 0.3~0.7MPa(36~100psi)(3.0~7.0bar) | 0.2~0.7MPa(28~100psi)(2.0~7.0bar) | ||||||
Proof pressure | 1.2MPa(175psi)(12bar) | |||||||
Temperature ℃ | -20~70 | |||||||
Speed range mm/s | 50~500 | 50~800 | ||||||
Cushion type | No cushion | Bumper | ||||||
Port size | Tube | M5×0.8 | ||||||
Add) Refer to P353 for detail of sensor switch. |
Bore size/Item | A | AB | AC | AD | AE | B | C | CA | D | DA | E | EA | EB | F | ||||
Back cover | U | CB | R | U/R | CB | |||||||||||||
10 | 74 | 87 | 74 | 28 | 46 | 11.5 | 9.5 | 22.5 | 12 | 3.3 | 13 | 4 | 20 | M4*0.7 | 15 | 16.5 | 7 | |
12 | 74 | 92 | 74 | 28 | 46 | 11.5 | 9.5 | 27.5 | 15 | 6.6 | 18 | 5 | 20 | M5*0.8 | 15 | 16.5 | 8 | |
16 | 76 | 94 | 76 | 28 | 48 | 12 | 9.5 | 27.5 | 18 | 6.6 | 18 | 5 | 20 | M5*0.8 | 15 | 16.5 | 8 |
Bore size/Item | FA | G | GA | K | KA | M | MA | P | PA | PB | R | ||
Back cover | U | CB | |||||||||||
10 | 3 | 11 | 4 | 3.3 | 5 | M8*1.0 | 8 | M5*0.8 | 7.5 | 5 | 18 | 14 | |
12 | 4 | 14 | 4 | 5 | 8 | M10*1.0 | 8 | M5*0.8 | 7.5 | 5 | 23 | 17 | |
16 | 4 | 14 | 4 | 5 | 8 | M10*1.0 | 8 | M5*0.8 | 7.5 | 5 | 23 | 20 |