Bore size [mm] | 8 | 10 | 12 | 16 | 20 | 25 | |
Type | Pneumatic | ||||||
Action | Double acting, Single rod | ||||||
Fluid | Air | ||||||
Proof pressure | 1.5 Mpa | ||||||
Max. operating pressure | 1.0 Mpa | ||||||
Min. operating pressure | Rubber bumper | 0.1 MPa | 0.08MPa | 0.05MPa | |||
Air cushion | — | 0.08MPa | 0.05MPa | ||||
Ambient and fluid temperature | Without auto switch: –20°C to 80°C (No freezing) | ||||||
With auto switch: –10°C to 60°C (No freezing) | |||||||
Lubricant | Not required (Non-lube) | ||||||
Stroke length tolerance | |||||||
Piston speed | 50 to 1500 mm/s | ||||||
Cushion | Rubber bumper | ||||||
— | Air cushion | ||||||
Allowable kinetic energy | Rubber bumper | 0.02J | 0.03J | 0.04J | 0.09J | 0.27J | 0.4J |
Air cushion | — | 0.17J | 0.19J | 0.4J | 0.66J | 0.97J |
Bore size | AM | BE | C | CD | EE | EW | F | G1 | G2 | H | (HR) | K | KK | KV | KW | NA | ND | RR | S | SW | U | WA | (WH) | (XC) | Z | ZZ |
8 | 12 | M12*1.25 | 4 | 4 | M5*0.8 | 8 | 12 | 7 | 5 | 28 | 13.4 | — | M4*0.7 | 19 | 6 | 15 | 12 | 10 | 46 | 7 | 6 | — | 16 | 64 | 76 | 86 |
10 | 12 | M12*1.25 | 4 | 4 | M5*0.8 | 8 | 12 | 7 | 5 | 28 | 14.2 | — | M4*0.7 | 19 | 6 | 15 | 12 | 10 | 46 | 7 | 6 | 10.5 | 16 | 64 | 76 | 86 |
12 | 16 | M16*1.5 | 6 | 6 | M5*0.8 | 12 | 17 | 8 | 6 | 38 | 14.2 | 5 | M6*1 | 24 | 8 | 18.3 | 16 | 14 | 50 | 10 | 9 | 9.5 | 22 | 75 | 91 | 105 |
16 | 16 | M16*1.5 | 6 | 6 | M5*0.8 | 12 | 17 | 8 | 6 | 38 | 14.2 | 5 | M6*1 | 24 | 8 | 18.3 | 16 | 13 | 56 | 10 | 9 | 9.5 | 22 | 82 | 98 | 111 |
20 | 20 | M22*1.5 | 8 | 8 | G1/8 | 16 | 20 | 8 | 8 | 44 | 17 | 6 | M8*1.25 | 32 | 11 | 24 | 22 | 11 | 62 | 13 | 12 | 13 | 24 | 95 | 115 | 126 |
25 | 22 | M22*1.5 | 8 | 8 | G1/8 | 16 | 22 | 8 | 8 | 50 | 20 | 8 | M10*1.25 | 32 | 11 | 30 | 22 | 11 | 65 | 17 | 12 | 13 | 28 | 104 | 126 | 137 |